Print the card
EPP
Description
Impulse relay with fixed duration - 4 CO contacts and 1 impulse contact.
Relay pluggable on socket including a withdrawal clasp and two guide pins.
Pluggable on the following sockets : EVPL5, EXCL5, or )EXL5.
Dimensions
Connection
Operation principle
Impulse relay with fixed duration.
Functions :
ET : impulse on voltage application
MT : impulse on voltage lack
Technical features
Function |
Impulse (ET - MT) |
Presentation |
under cover |
Connection |
on front or rear wiring socket |
Number of mechanical operations |
30.000.000 |
Operating temperature |
- 5°C to + 40°C |
Storage temperature |
- 40°C to + 70°C |
Climatic protection |
optional reinforced climatic protection |
Shock voltage |
3 KV (wave 1,2/50 µs) |
Dielectric strength |
2200 V eff 50 Hz |
Insulation resistance |
> 20.000 MOhms |
Weight |
180 g. |
Protection level |
IP 40 (according to NFC 20-010) |
Resistance to mechanical shocks |
severity 50 A (NFC 20-608 & CEI 68-2-27) |
Resistance to vibrations |
0,35 mm / 10-55 Hz |
Coil data
|
Direct current |
Alternative current |
Min. nominal voltage DC |
12 V |
12 V |
Min. nominal voltage AC |
230 V |
380 V - 50/60 Hz |
Operating range |
-20/+10% of nominal voltage |
Power requirement |
2,7 W (12-24-48 V) |
3,7 VA (125-220-380 V) |
|
Contacts
Number of contacts |
1 |
Max. load current |
5 A inst / 2 A impulse |
Low power switching |
0,1 VA with min voltage 1 V or I min 1 mA |
Response time (bounce time not included) |
DC > 21 ms - AC < 17 ms |
Contacts rating
DIRECT CURRENT |
instantaneous contacts - connection on DC |
X 1.000.000 impulse contacts |
|
|
|
ALTERNATIVE CURRENT |
connection on AC |
X 1.000.000 impulse contacts |
|
|
|
Versions
. EPP relay with reinforced climatic protection
. EPP with specific characteristics (voltage, frequency)
Homologations & conformities :
* CEI 255-1-00
* NFC 45-250
Non-contractual document - characteristics to be confirmed before order
TEC AUTOMATISMES reserves the right to modify description and specifications without notice