Print the card
CAP
Description
Impulse relay with fixed duration. 1 impulse contact and 2 CO contacts.
Pluggable on socket with a withdrawal clasp and square guide pins which can act as a key to ensure that the correct relay is used at the correct voltage (see our withdrawal guide in the technical support pages of this site)
Pluggable on the following sockets : EVB1/CA, ERC1CA or ERDL1CA.
Dimensions
Connection
Operation principle
Impulse relay with fixed duration :
* interval between 2 operations >= 1 s
* duration of the impulse contact >= 200 ms
Technical features
Function |
Impulse (ET - MT) |
Presentation |
under cover |
Connection |
on front or rear wiring socket |
Number of mechanical operations |
35.000.000 |
Operating temperature |
- 5°C to + 40°C |
Storage temperature |
- 40°C to + 70°C |
Climatic protection |
optional reinforced climatic protection |
Shock voltage |
3 KV (wave 1,2/50 µs) |
Dielectric strength |
2200 V eff |
Insulation resistance |
NFC 45-202 & VDE0110 : C250 |
Weight |
200 g. |
Protection level |
IP 40 (according to NFC 20-010) |
Resistance to mechanical shocks |
severity 50 A (CEI 68-2-27) |
Resistance to vibrations |
0.35 mm / 10-55Hz (CEI 38-2-6) |
Coil data
|
Direct current |
Alternative current |
Min. nominal voltage DC |
12 V |
12 V |
Min. nominal voltage AC |
220 V |
230 V 50-60 Hz |
Operating range |
-20/+10% of nominal voltage |
Power requirement |
2,2 W +/- 20% |
3 VA +/- 20% |
|
Contacts
Number of contacts |
1 |
Max. load current |
8 A inst. / 4 A impulse |
Low power switching |
0,1 VA with min voltage 1 V and/or I min 1 mA |
Response time (bounce time not included) |
DC < 9 ms - AC < 24 ms |
Contacts rating
DIRECT CURRENT |
instantaneous contacts - connection on DC |
X 1.000.000 impulse contacts |
|
|
|
ALTERNATIVE CURRENT |
connection on AC |
X 1.000.000 impulse contacts |
|
|
|
Versions
* CAP relay with reinforced climatic protection
* CAP relay with 3 instantaneous contacts and 1 impulse contact
Homologations & conformities :
* CEI 255-1-00
* NFC 45-250
Non-contractual document - characteristics to be confirmed before order
TEC AUTOMATISMES reserves the right to modify description and specifications without notice